Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
2 ratings:
 3 out of 5     Rate this Document

Configuring the PXI-8106 to Operate as a Real-Time Controller

Hardware: PXI/CompactPCI>>Controllers

Problem:
I have a PXI-8106 and have selected the options in the BIOS boot into the Real-Time O/S. It appears to enter safe mode, but I cannot seem to find it from my host machine. I’ve verified that I’m on the same subnet and other networking settings are correct. What am I doing wrong?

Solution:
In order to install LabVIEW Real-Time onto a PXI Controller preloaded with Microsoft Windows, you need to purchase the LabVIEW Real-Time Deployment License for NI PXI Controllers.

Then, make sure you have a LabVIEW or CVI Real-Time Module version that will support the PXI-8106RT. The PXI-8106RT is natively supported by LabVIEW Real-Time 8.5, and with the proper Target Software CD, LabVIEW Real-Time 8.2 and CVI Real-Time 8.1 or higher will support the PXI Embedded Controller 8106. Using the PXI-8106 with previous version of LabVIEW/CVI Real-Time could result in connection problems to the real-time target.

Note: If you do not have LabVIEW Real-Time 8.2 or CVI Real-Time 8.1, please contact National Instruments customer service in your country.

Related Links:
Product Page: NI PXI-8106 Embedded Controller
Product Page: Real-Time Measurement and Control
KnowledgeBase 47IC8SCW: Why is my Real-Time Target Not Listed in MAX 4.2 When in Safe Mode or Unconfigured?
KnowledgeBase 4OJGLEL3: What Version of LabVIEW Real-Time is Supported by My PXI Controller?

 



Attachments:





Report Date: 03/18/2007
Last Updated: 01/26/2009
Document ID: 47HFFLF7

Your Feedback! poor Poor  |  Excellent excellent   Yes No