Problem:
I am trying to deploy my VI to my Wireless Sensor Network(WSN) target node and when I hit the run button I receive the following pop-up error. What can I do to fix this problem?



Solution:
The reason this error is appearing is because the node VI must have only one connection in the connector pane.  Ensure that the enum is selected as the connection for upper left most connection within the connector pane as shown in the image below. Check that there is not another connection listed within the connector pane, or that the terminal is not wired to a different control type other than an enum.

Note: The enumerated control on the front panel is often hidden. To show the control, navigate to the block diagram,right click the enum and select Show Control.