Connector Pane of my VI is not in the Expected Format for a LabVIEW WSN Top Level VIPrimary Software: LabVIEW Development Systems>>LabVIEW Professional Development SystemPrimary Software Version: 1.0 Primary Software Fixed Version: N/A Secondary Software: Driver Software>>NI-WSN
Problem: I am trying to deploy my VI to my Wireless Sensor Network(WSN) target node and when I hit the run button I receive the following pop-up error. What can I do to fix this problem?
Solution: The reason this error is appearing is because the node VI must have only one connection in the connector pane. Ensure that the enum is selected as the connection for upper left most connection within the connector pane as shown in the image below. Check that there is not another connection listed within the connector pane, or that the terminal is not wired to a different control type other than an enum. Note: The enumerated control on the front panel is often hidden. To show the control, navigate to the block diagram,right click the enum and select Show Control. ![]() Related Links: KnowledgeBase 4XJBJ5HN: How Do I Configure My Time Server on the WSN-9791 Gateway? Attachments:
Report Date: 06/30/2009 Last Updated: 07/07/2009 Document ID: 4YTFARS0 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||