Running the Test Panel on an AT-AO-10 Causes a Reboot Hardware: Legacy DAQ Devices>>Analog Output>>AT-AO-10
Problem: I am using either NI-DAQ 6.7 or 6.8.1 and running the test panel on the AT-AO-10, and this causes my system to instantly reboot. I tested this on several different computers and several different AT-AO-10 cards with the same result. Solution: On some computers there is an option in the BIOS to reserve IRQs for legacy ISA and EISA cards. You must enable this item. This should solve the problem that you are seeing. Note that this option is not available in all BIOS, it is available in most Dell and HP computers. Related Links: Product Manual: AT-AO-10 Attachments:
Report Date: 11/20/2000 Last Updated: 10/13/2006 Document ID: 23JETBQ1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||