Compatibility Information of LabVIEW Real-Time with NI-RIO

Primary Software: LabVIEW Modules>>Real-Time Module
Primary Software Version: 7.1
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: CompactRIO, Reconfigurable I/O (RIO)>>R Series

Problem: I am not able to use LabVIEW 7.1 and program FPGA’s using NI-RIO 2.X and higher through a real time controller. It requires an upgrade of LabVIEW. What is the problem?

Solution:
NI-RIO 2.0 for Real-Time does not support LabVIEW Real-Time 7.1. It requires you to have LabVIEW and Real-Time module version 7.1.1 or higher. For example if you have NI-RIO 2.0 and a cRIO controller that you want to program, you will have to upgrade to 7.1.1 or higher. NI-RIO 2.0 will only work with LabVIEW 7.1 if you are targeting the FPGA from a windows machine. An example of this is targeting a PCI 7831R or using an R series expansion chassis from a windows machine.