Error at Line Set Attribute for TIO Application

Primary Software: Driver Software>>NI-DAQ
Primary Software Version: 4.6.1
Primary Software Fixed Version: 6.9.3
Secondary Software: N/A
Hardware: Counter/Timers (TIO)>>Devices>>PCI-6602, Counter/Timers (TIO)>>Devices>>PCI-6608

Problem: I have a Traditional DAQ Counter/Timer VI that worked in LabVIEW 6.1 but errors at Line Set Attribute in LabVIEW 8

Solution: There are two versions of the Line Set Attribute VI. The older one uses a Code Interface Node to call lchaattr.lsb:



The newer version of this VI uses a Call Library Function Node to call lvdaq.dll:



To make the older DAQ program compatible with newer versions, you should replace the older Line Set Attribute.vi with the newer one.