Can I Use Four SC-2345's with One 64 Channel DAQ Board?Hardware: SCC>>Carriers>>SC-2345
Problem: I have a 64 channel DAQ Device and I need signal conditioning for all 64 channels. Can I use 4 SC-2345's? Solution: Yes. Besides the DAQ Device, SCC Modules, and panelettes, here is the equipment you will need:
Keep in mind that you should probably use power options 2 or 3. Power option 1 is where the SC-2345 is powered by the DAQ Device. Most PCI/PXI DAQ Devices can only source about 5 Watts (5 Volts at 1 Amp). Depending on your configuration, you may be able to power some of your SC Carriers with your DAQ Device. Users will be liable for any damages caused by exceeding specifications. The possible 64 Channel DAQ Devices include, but are not limited to the 6071E, 6061E, 6031E, and the 6033E. Related Links: KnowledgeBase 2E4DTDS0: Power Options for an SC-2345 Carrier Product Manuals: SC-2345 User Manual Attachments:
Report Date: 02/04/2003 Last Updated: 09/27/2004 Document ID: 2U35O2QG |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||