Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
This Document is not yet Rated  Rate this Document

Can I Use Four SC-2345's with One 64 Channel DAQ Board?

Hardware: SCC>>Carriers>>SC-2345

Problem: I have a 64 channel DAQ Device and I need signal conditioning for all 64 channels. Can I use 4 SC-2345's?

Solution: Yes. Besides the DAQ Device, SCC Modules, and panelettes, here is the equipment you will need:
  • 1 SC-2056 adapter (P/N 776335-96) - This is the cable adapter that splits the 100-pin into four 50-pin adapters.
  • 4 SH6850 cables (P/N 776784-01) - These cables convert the 50-pin adapters to connect to the SC-2345 carriers.
  • SH100100 shielded cable (P/N 182853-01) - This cables your 64 channel DAQ Device to the SC-2056.
  • 4 SC-2345 Carriers (P/N is dependent on which power option the select)

Keep in mind that you should probably use power options 2 or 3. Power option 1 is where the SC-2345 is powered by the DAQ Device. Most PCI/PXI DAQ Devices can only source about 5 Watts (5 Volts at 1 Amp). Depending on your configuration, you may be able to power some of your SC Carriers with your DAQ Device. Users will be liable for any damages caused by exceeding specifications.

The possible 64 Channel DAQ Devices include, but are not limited to the 6071E, 6061E, 6031E, and the 6033E.

Related Links: KnowledgeBase 2E4DTDS0: Power Options for an SC-2345 Carrier
Product Manuals: SC-2345 User Manual


Attachments:





Report Date: 02/04/2003
Last Updated: 09/27/2004
Document ID: 2U35O2QG

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit