Downgrade Problems With cDAQ and TEDs Bitstreams in NI-DAQmx 8.1 or 8.3Primary Software: Driver Software>>NI-DAQmxPrimary Software Version: 8.3 Primary Software Fixed Version: N/A Secondary Software: N/A Hardware: CompactDAQ
Problem: I am using a cDAQ chassis and either downgraded from NI-DAQmx 8.5 or later or am trying to import a Measurement and Automation configuration exported from NI-DAQmx 8.5 or later. However when I do so the configuration seems to be corrupt or will not import successfully. How do I import my configuration or downgrade from NI-DAQmx 8.5 or later to NI-DAQmx 8.1 or 8.3? Solution: When downgrading to NI-DAQmx 8.1 or NI-DAQmx 8.3 from DAQmx 8.5 or later on a system that has a cDAQ chassis with a module that is not supported in DAQmx 8.1 or DAQmx 8.3, the cDAQ chassis configuration will become corrupted. Workaround: Delete the cDAQ chassis in Measurement and Automation Explorer and reconfigure it. The following problems will occur when importing an nce file created in DAQmx 8.5 or later to a system with DAQmx 8.1 or DAQmx 8.3 installed:
Related Links: Attachments:
Report Date: 03/01/2007 Last Updated: 03/01/2007 Document ID: 470A1ENO |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||