6533 and 6534 Terminal Name Equivalents for DAQmxHardware: Digital I/O (DIO)>>High-Speed>>PCI-6534, Digital I/O (DIO)>>High-Speed>>PCI-6533
Problem: I want to program my 6533/6534 using DAQmx but I am having problems accessing some pins. In LabVIEW I only see PFI lines as options, while in the 6533/6534 User Manual for Traditional NI-DAQ I see other names like ACK, REQ, PCLK and STOPTRIG. What is the relationship between the PFI lines and these terminals? Solution: With NI-DAQmx, National Instruments has revised its terminal names so that they are easier to understand and more consistent. Below you will find a list of the 653x DAQmx terminal name equivalents for the Traditional NI-DAQ (Legacy) terminal names:
For a more detailed list refer to the DAQmx Help under Start»Programs»National Instruments»NI DAQ»NI DAQmx Help. Navigate to NI-DAQmx Device Terminals»Terminal Name Equivalents. Related Links:
Attachments:
Report Date: 04/14/2005 Last Updated: 08/30/2008 Document ID: 3KDGH0MP |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||