Academic Company Events Community Support Solutions Products & Services Contact NI MyNI
2 ratings:
 5 out of 5   

Archived: Error 1045 - Unknown System Error in TestStand When Using the Assemble Test VIs Tool within TestStand

This document has been archived and is no longer updated by National Instruments



Primary Software: TestStand
Primary Software Version: 2.0
Primary Software Fixed Version: N/A
Secondary Software:

Problem:
While trying to use the Assemble Test VIs tool from within TestStand, I select a sequence file that contains an empty sequence and I get the following error:

Error 1045 - Unknown System Error in TestStand

For example, if I choose to run the Assemble Test VIs tools on a process model that contains an empty MainSequence, I get this error. How do I fix this?


Solution:
To fix this problem, replace the VI called TestStand Look for Sequence Calls and Append.vi located in both the <TestStand>\Components\NI\Tools\VIPackager and <TestStand>\Components\User\Tools\VIPackager directories with the attached VI.

Note: You might or might not have a <TestStand>\Components\User\Tools\VIPackager directory.


Related Links:

Attachments:



TestStand - Look for Sequence Calls and Append.vi




Report Date: 08/29/2001
Last Updated: 03/25/2015
Document ID: 2CSDSMQR

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit