Why Do I Get Error 1031 When I Click on the Configure Button in the Select Signal Window in BioBench? Primary Software: Other NI Software>>BioBenchPrimary Software Version: 1.2 Primary Software Fixed Version: N/A Secondary Software:
Problem: I get error 1031 when I click on the Configure button in the "Select Signal" window in BioBench. How do I fix this? Solution: There are two possible causes for this error. First, you may not have wired the connector pane for your configuration VI. Also, the representations that you chose for "Plot No." and "Sample Rate" in your configuration VI may be incorrect. They should be I-32 and SGL respectively. Refer to the Troubleshooting Q&A section of the Plug-In Analysis tutorial for more information. Related Links: Developer Zone Tutorial: Plug-In Analysis in BioBench 1.2 BioBench User Manual Attachments: