DAQmx Task Gives Error -200077 When Creating a Custom ScalePrimary Software: Utility Software>>Measurement & Automation ExplorerPrimary Software Version: 4.3 Primary Software Fixed Version: N/A Secondary Software: N/A Hardware: Multifunction DAQ (MIO)>>M Series>>USB-6259
Problem: I am trying to create a custom scale for the signals acquired from my USB 6259. I have created an analog input task in Measurement & Automation Explorer, and I have selected custom scale. I am using a map range scale to scale values proportionally from a range of pre-scaled values to a range of scaled values. My pre-scaled values are +/- 5V and my scaled values go from 0 to 200 volts. I have my signal input range set to +/- 5V. However, when I try to save or run the Task I am getting the following error: Error -200077 occured at DAQ Assistant Possible Reason(s): Measurements: Requested value is not a supported value for this property. Solution: When the signal input range does not match the scaled values, as in the figure below, error -200077 can occur. Related Links: Knowledgebase 4XC8EAN8: How do I make a custom scale in the Measurement and Automation Explorer (MAX)? Knowledgebase 30BG5VMW: What Are Custom Scales and How Do I Use Them? Attachments:
Report Date: 12/31/2007 Last Updated: 01/19/2010 Document ID: 4GUERUMA |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||