Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
3 rating:
 1 out of 5     Rate this Document

Why Do I Receive a Run-Time Version Error in TestStand When Loading a VI?

Primary Software: TestStand
Primary Software Version: 1.0
Primary Software Fixed Version: N/A
Secondary Software: LabVIEW Run-Time Engine, LabVIEW Development Systems>>LabVIEW Full Development System, LabVIEW Development Systems>>LabVIEW Base Package, LabVIEW Development Systems>>LabVIEW Professional Development System

Problem:
When I load a LabVIEW VI in TestStand using the Run-Time Engine I get the following error.

Error 0: Unable to load VI VI_name with the Run-Time Engine. It is possible that the version of the VI or one of its subVIs is not the same as the LabVIEW Run-Time Engine version.

The VI that I am trying to load is the same version as the Run-Time engine. What can I do to avoid this error?

Solution:
This error can occur when you attempt to load a VI that is in a LabVIEW library while using the LabVIEW Run-Time Engine.  If you see this error, save the LabVIEW library in addition to the individual VI you are attempting to load. These actions should correct the problem.