Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
This Document is not yet Rated  Rate this Document

Communication Lines Not Supported by National Instruments Isolated Serial Boards

Hardware: Serial

Problem:
Which communication lines are not supported by National Instruments isolated serial boards?

Solution:
The isolation is achieved through optocouplers, which are rather expensive. It is for this reason that 8-port boards do not come with isolation. Also, since these boards are most commonly used in industrial applications, where certain handshaking lines are not used, the following lines are not supported by the isolated version of the serial boards: DSR, DTR, DCD, and RI.

This information can be also found in the "Connector Descriptions » DB-9 Connector" section of the Serial Hardware and Software for Windows Help file.

Related Links:
Product Reference Manuals: Serial Hardware and Software for Windows Help

Attachments:





Report Date: 03/27/2006
Last Updated: 03/31/2006
Document ID: 3VQFQ6F3

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5