NI Assistant Host Crash in LabVIEW 8.2.1 When Using SignalExpress Express VIsPrimary Software: LabVIEW Signal Express>>Development SystemPrimary Software Version: N/A Primary Software Fixed Version: N/A Secondary Software: LabVIEW Toolkits>>Control Design Toolkit, LabVIEW Toolkits>>System Identification Toolkit, LabVIEW Development Systems
Problem: I installed LabVIEW 8.2.1 and either Control Design Toolkit 2.1.1 or System Identification Toolkit 3.0.1. When I try to use the VIs found in the function palette under Express»SignalExpress»Analog »Frequency-Domain Measurements, I see a crash in the NI Assistant Host. This does not seem to affect the rest of LabVIEW; how can I use these VIs? Solution: The express VIs found in the Express»SignalExpress»Analog»Frequency-Domain Measurements palette appear by mistake and should not be used. You will have access to these VIs if you have installed and licensed SignalExpress 2.x. Related Links: NI LabVIEW Control Design and Simulation Module KnowledgeBase 443DKECW: LabVIEW Control Design Toolkit 2.1.x Readme Files NI LabVIEW System Identification Toolkit NI LabVIEW SignalExpress Attachments:
Report Date: 08/30/2007 Last Updated: 10/16/2008 Document ID: 46PT8W9 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||