Known Compatibility Issues with TestStand and LabVIEW 8.6
Primary Software: TestStand
Primary Software Version: 1.0
Primary Software Fixed Version: N/A
Secondary Software: LabVIEW Run-Time Engine, LabVIEW Development Systems>>LabVIEW Base Package
Problem:
I am trying to find a list of known compatibility issues with TestStand and LabVIEW 8.6. Where are these issues documented?
Solution: The following are known issues when using TestStand with LabVIEW 8.6:
- Selecting a VI which has an I/O control on the connector pane causes TestStand to become unresponsive for several seconds. This issue is caused by a change in LabVIEW 8.6 to the way that TestStand determines if a connector pane has been changed. This issue has been fixed in the LabVIEW 8.6f1 Patch. Please install the DevSystemWithRunTimePatch and then install the LabVIEW 8.6f1 Run-Time Engine. After installing these two items, all deployments build from patched systems will also include the fix.
- Installing the Desktop Execution Trace Toolkit version 1.0 can cause error -18002: VI Server Access Denied. See KnowledgeBase 4U49Q33Y: VI Server or Code Generation Errors after Installing Desktop Execution Trace Toolkit 1.0 for more information
Related Links:
Drivers and Updates: LabVIEW 8.6f1 Patch
Drivers and Updates: LabVIEW 8.6f1 Run-Time Engine
KnowledgeBase 4U49Q33Y: VI Server or Code Generation Errors after Installing Desktop Execution Trace Toolkit 1.0
Attachments:
Report Date: 09/18/2008
Last Updated: 02/06/2009
Document ID: 4PH891T3