I am trying to find a list of known compatibility issues with TestStand and LabVIEW 8.6. Where are these issues documented?



Solution:
The following are known issues when using TestStand with LabVIEW 8.6:
  1. Selecting a VI which has an I/O control on the connector pane causes TestStand to become unresponsive for several seconds.  This issue is caused by a change in LabVIEW 8.6 to the way that TestStand determines if a connector pane has been changed.  This issue has been fixed in the LabVIEW 8.6f1 Patch.  Please install the DevSystemWithRunTimePatch and then install the LabVIEW 8.6f1 Run-Time Engine.  After installing these two items, all deployments build from patched systems will also include the fix.
  2. Installing the Desktop Execution Trace Toolkit version 1.0 can cause error -18002: VI Server Access Denied. See KnowledgeBase 4U49Q33Y: VI Server or Code Generation Errors after Installing Desktop Execution Trace Toolkit 1.0 for more information


Related Links:


Drivers and Updates: LabVIEW 8.6f1 Patch
Drivers and Updates: LabVIEW 8.6f1 Run-Time Engine
KnowledgeBase 4U49Q33Y: VI Server or Code Generation Errors after Installing Desktop Execution Trace Toolkit 1.0



Attachments:





Report Date: 09/18/2008
Last Updated: 02/06/2009
Document ID: 4PH891T3

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit