How to Update a DASYLab Worksheet if the Hardware Configuration has Changed

Primary Software: Other NI Software>>DASYLab
Primary Software Version: 6.00.03
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem: The worksheet is not running properly after the hardware configuration has changed.

Solution: The worksheet contains references to acquisition hardware modules in your computer. If the hardware configuration has significantly changed, the worksheet may try to use nonexistant data acquisition devices.
You can update the worksheet for a new configuration with the following procedure :
1. Backup the original worksheet for safety (save to a different name or folder).
2. Remove all NI-DAQ modules from the worksheet.
3. Open NI-DAQ - Hardware Configuration and click onHardware Reset. This will remove hardware references and configuration information that is stored in the worksheet.
4. Add all required NI-DAQ modules and re-connect in the worksheet.
5. Setup in NI-DAQ - Measurement Setup and Hardware Configuration.

Related Links:

Attachments:





Report Date: 06/18/2002
Last Updated: 12/07/2004