AT E Series Devices Do Not Work Correctly with NI-DAQ 7.0 or 7.1Primary Software: Driver Software>>NI-DAQPrimary Software Version: 7.0 Primary Software Fixed Version: 7.2 Secondary Software: N/A Hardware: Multifunction DAQ (MIO)>>E Series, Multifunction DAQ (MIO)>>E Series>>AT-MIO-16XE-10, Multifunction DAQ (MIO)>>E Series>>AT-MIO-16E-1, Multifunction DAQ (MIO)>>E Series>>AT-MIO-64E-3, Multifunction DAQ (MIO)>>E Series>>AT-MIO-16DE-10, Multifunction DAQ (MIO)>>E Series>>AT-MIO-16E-10, Multifunction DAQ (MIO)>>E Series>>AT-MIO-16XE-50, Multifunction DAQ (MIO)>>E Series>>AT-MIO-16E-2, Legacy DAQ Devices>>Multifunction DAQ>>AT-AI-16XE-10
Problem: When using AT E Series devices with NI-DAQ 7.0 or 7.1, I receive errors from the Test Panels in Measurement & Automation Explorer (MAX) that state: Device is not responding to the first DMA channelAccording to the Device Manager, all 3 DMA channels seem to be configured correctly, but the MAX Test Panels report that the device is not responding to the first DMA channel. I also receive Error 10800 (timeout) in DAQ_Op calls with any AT E-Series device in NI-DAQ 7.0 or 7.1. How do I correct these issues? Solution: You can still acquire data with the AT E Series device, but the device cannot use DMA channels. PCI and PXI E Series devices are not affected by this issue. To resolve these issues, upgrade to NI-DAQ 7.2 (linked below). Related Links: NI-DAQ Version 7.2 for Windows 2000/NT/XP Attachments:
Report Date: 05/14/2004 Last Updated: 06/28/2004 Document ID: 34F82RTY |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||