Can I Use the 1 MHz Internal Clock as the Source on the DAQCard-700?

Primary Software: Driver Software>>NI-DAQ
Primary Software Version: 4.9.0
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: Legacy DAQ Devices>>Multifunction DAQ>>DAQCard-700

Problem: How do I use the internal 1Mhz clock on the DAQcard-700 as the source for counter 1 using NI-DAQ calls?

Solution: This functionality has been added to NI-DAQ for PC compatibles in version 4.8.0 and later. To control whether the internal clock, or the I/O Connector (CLK1 pin) will be used for the source of counter 1, call Set_DAQ_Device_Info. The infoType ND_COUNTER_1_SOURCE allows either ND_INTERNAL_TIMER for the internal clock as the CLK1 source, or ND_IO_CONNECTOR to use an external source.

See the NI-DAQ Function Reference Manual (linked below) for more details.