Problem:
What are the differences between the Embedded, Snapshot, and Monitor options in the Web Publishing Tool?

Solution:
The Embedded option embeds the front panel of the VI so clients can view and control the front panel remotely using a browser. The VI must be in memory on the server computer so clients can view and control the front panel. You can embed only standard VIs for remote front panel connections. For example, you cannot embed a polymorphic VI.

Note: The Embedded option is available only in the LabVIEW Full and Professional Development Systems. It also requires the LabVIEW Run-Time Engine to be installed on the computer that is viewing the Remote Front Panel. Further, the Embedded option requires one Remote Panel Connection license for each Remote Panel session.

The Snapshot option displays a static image of the front panel in a browser. Snapshot does not allow you to interact with the controls of the VI from the browser. User can use the refresh button on the web browser to view changes on the front panel of the VI.

The Monitor option displays an animated snapshot that updates continuously. Monitor does not allow you to interact with the controls of the VI from the browser.

Summary of Web Publishing Tool Options
Option
Embedded
Snapshot
Monitor
Remote VI Control
Yes
No
No
Requires Remote Panel License
Yes
No
No
Requires Run-Time Engine
Yes
No
No
Compatible with Netscape 4.x
Yes
Yes
Yes
Compatible with Netscape 6.x
Yes
Yes
No
Compatible with Internet Explorer
Yes
Yes
Possible*


Related Links:
KnowledgeBase S134FOAVJ: My Web Browser Image Does Not Animate When Using the .monitor URL with the Internet Toolkit or the LabVIEW HTTP Server
KnowledgeBase 2ZS7R5DT: Can I Use Remote Panels To Communicate Between Different Versions of LabVIEW?
NI LabVIEW Internet Connectivity Toolkit
NI LabWindows/CVI Enterprise Connectivity Toolkit

Attachments:





Report Date: 05/29/2002
Last Updated: 12/29/2016
Document ID: 2LSFN7YP

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit