"Cannot find 'test' (or one of its components)" Error When Running Mobile Module Executable

Primary Software: LabVIEW Modules>>PDA Module
Primary Software Version: 8.2
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
I am able to build my Mobile Module executable successfully, but upon transferring it to my PDA and trying to run it, I receive the following error message:

Cannot find 'test' (or one of its components)


 Why do I receive this error?

Solution:
The minimum operating system for the LabVIEW Mobile Module 8.x is PocketPC 2003, which is based on Windows CE 4.2. If you attempt to run executables built with the LabVIEW Mobile Module on earlier operating systems, you will receive the above mentioned error message.

Please see the related link below for the minimum supported operating system for various versions of the LabVIEW Mobile Module.

Related Links:
KnowledgeBase 3ANADAKN: LabVIEW Mobile Module Software Requirements and Supported Devices