Why do I get Error 7 when trying to save to a network directory from my LabVIEW Real-Time controller.

Primary Software: LabVIEW Modules>>Real-Time Module
Primary Software Version: 8.2.1
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: Compact FieldPoint>>Controllers>>cFP-2120

Problem:
I am running an LabVIEW application on a Real-Time target (Fieldpoint controller, Real-Time PXI, cRIO, Compact Vision System) and I want to save a file directly to my Windows PC. I have tried using the Open/Create/Replace function with the path set to \\xxx.xxx.xxx.xxx\test\rttest.txt  where xxx.xxx.xxx.xxx is the IP address of my computer, but it always returns Error 7: File not found.

Solution:
The Real Time Operating System does not support writing to network shares. You have to write the file locally then transfer it to the Windows PC via FTP.

Related Links: http://digital.ni.com/public.nsf/allkb/4DCF9D581C491E9F8625711B005FA539?OpenDocument