Problem:
I am using MC Generic.vi to format an object to transmit to my ECU. The inputs to the VI do not include the command counter. When I add the command counter to the data field, I get an error that the message type is unsupported. How do I set up this VI to correctly include the command counter?

Solution:
The command counter will automatically be incremented by LabVIEW as objects are sent to the ECU. The following code snippet is a basic example:



This will send the command 0x02 with the following data bytes: {0x01, 0x02, 0x03, 0x04, 0x05}


Related Links:
Product Manuals: ECU Measurement and Calibration Toolkit
Products and Services: NI ECU Measurement and Calibration Toolkit
KnowledgeBase 464FPRJL: Using the ECU MC Toolkit with cRIO 985x C-Series Hardware
KnowledgeBase 3ZG4RUE6: NI ECU M&C Toolkit Examples Do Not Run When Using My ECU
KnowledgeBase 7EBB3CB3: How Can I Enable LabVIEW 2016 Support for ECU Measurement and Calibration Toolkit (ECUMC) 15.0?
Example Program: How to use the ECU MC Toolkit with cRIO 985x C-Series Hardware?