Error -1013 on a Real-Time Target Primary Software: LabVIEW Modules>>Real-Time ModulePrimary Software Version: 8.5 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: Why Do I Receive Error -1013 When I Attempt to Use a Front Panel Property Node on a Real-Time Target? Solution: Access to front panel properties and methods are not supported on Real-Time operating systems such as ETS and VxWorks. The reason is that there is no actual front panel residing on the target. When a VI is deployed to a target, it is compiled into something other than a VI. This object is executed, and information is sent to a host computer. The host computer retains a copy of the VI so that it can construct a front panel with updated values. Related Links: LabVIEW 8.5 Help: Unsupported LabVIEW Features (ETS) (RT Module) LabVIEW 8.5 Help: Unsupported LabVIEW Features (VxWorks) (RT Module) Attachments:
Report Date: 10/23/2007 Last Updated: 01/29/2008 Document ID: 4EMGPJCY |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||