Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
1 ratings:
 2 out of 5     Rate this Document

The Icon Editor Shipped with LabWindows/CVI 9.0.1 Returns Error -14 and Does Not Run

Primary Software: LabWindows/CVI Development Systems>>Full Development System
Primary Software Version: N/A
Primary Software Fixed Version: N/A
Secondary Software: N/A

Problem:
When I launch the Icon Editor from the tools menu in the LabWindows/CVI environment or from the Start Menu, I get the following error:

Error Code = -14. Value is invalid or our of range.

How can I fix this issue?

Solution:
To fix this issue, you need to open the Iconedit example in the \apps\iconedit directory. Once opened, set the build configuration to Release through the Build»Configuration»Release menu item. Once the configuration has been set to Release, rebuild the Iconedit project. You will now be able to run the Icon Editor from the Tools menu in the LabWindows/CVI environment, as well as from the Start Menu.

If you get a message saying that the iconedit.exe could not be opened, rename or delete the existing iconedit.exe and rebuild the project.  This executable will then be recreated and the icon editor will launch.

Related Links:
What's New in NI LabWindows/CVI?
KnowledgeBase 0ZG8KQU9: Where is the CVI Icon Editor?

Attachments:





Report Date: 05/12/2009
Last Updated: 09/03/2009
Document ID: 4XB9PPXU

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit