Primary Software: Driver Software>>NI-RIO
Primary Software Version: 1.3
Primary Software Fixed Version: 1.3
Secondary Software: Driver Software>>NI-VISA, Driver Software>>NI-IMAQ for IEEE-1394
Hardware: Image Acquisition (IMAQ)>>Compact Vision System

Problem: The Compact Vision System may hang when connecting from Vision Builder AI or when running LabVIEW RT code that uses the FPGA VIs.

Solution: This problem could be caused by incompatible versions of NI-VISA and NI-RIO. If you are using NI-VISA 3.3, then NI-RIO 1.3 or later is required. Download and install the latest version of NI-RIO from the link below. After installing NI-RIO on the host system, connect to the CVS from the Measurement and Automation Explorer and update the NI-RIO version on the CVS.


Related Links:
Drivers and Updates: NI-RIO
Drivers and Updates: NI-VISA
Drivers and Updates: NI-IMAQ for IEEE 1394