Error When Connecting to the CVS from Vision Builder AI or When Downloading LabVIEW RT CodePrimary Software: Driver Software>>NI-RIOPrimary Software Version: 1.3 Primary Software Fixed Version: 1.3 Secondary Software: Driver Software>>NI-VISA, Driver Software>>NI-IMAQ for IEEE-1394 Hardware: Image Acquisition (IMAQ)>>Compact Vision System
Problem: The Compact Vision System may hang when connecting from Vision Builder AI or when running LabVIEW RT code that uses the FPGA VIs. Solution: This problem could be caused by incompatible versions of NI-VISA and NI-RIO. If you are using NI-VISA 3.3, then NI-RIO 1.3 or later is required. Download and install the latest version of NI-RIO from the link below. After installing NI-RIO on the host system, connect to the CVS from the Measurement and Automation Explorer and update the NI-RIO version on the CVS. Related Links: Drivers and Updates: NI-RIO Drivers and Updates: NI-VISA Drivers and Updates: NI-IMAQ for IEEE 1394 Attachments:
Report Date: 06/09/2005 Last Updated: 06/17/2005 Document ID: 3M8FBCV3 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||