Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI
2 ratings:
 2 out of 5     Rate this Document

FieldPoint: "Remote Panel Connection Exceedes Maximum Number of Licenses"

Primary Software: LabVIEW Development Systems>>Professional Development System
Primary Software Version: 8.0
Primary Software Fixed Version: N/A
Secondary Software: N/A
Hardware: FieldPoint

Problem: I have LabVIEW 8.0 Professional Development System which gives me a total of 5 remote panel licenses. I am fine using this feature on the host computer; however, when I download the VI to the FieldPoint, I am no longer able to open 5 Internet instances. Instead, I am only able to open up one, and then after that I receive the message "Remote Panel Connection Exceedes Maximum Number of Licenses." Why am I not able to open all 5?

Solution: The reason that you are not able to open 5 instances at a time is because the application is built into an executable and then deployed to the FieldPoint device. When an application is built into an executable, it becomes a common application that can be run on any computer. However, this also means that it loses its association to the license manager on your system and its relation to the Professional Development System, and therefore defaults to one license for the application. The only way to use the 5 license feature is to run the VI from the development machine.

Related Links:

Attachments:





Report Date: 03/22/2006
Last Updated: 09/15/2006
Document ID: 3VLFTAIH

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
  1 2 3 4 5
Please Contact NI for all product and support inquiries.submit