ActiveX Automation Server Error 18351 on Deployed TestStand TargetPrimary Software: TestStandPrimary Software Version: 3.5 Primary Software Fixed Version: N/A Secondary Software: N/A
Problem: After I deploy a working sequence to a target computer, I'm getting the following error message: Error loading type library/DLL. Error Code: -18351; An error occurred reading an ActiveX Automation server type library Step 'Read Database Option - Construct' of sequence 'Get Database Options' in 'SequentialModel.Seq' How do I fix it? Solution: The error occurs when TestStand is having trouble accessing the Database activeX server. Here's a couple things to try: Navigate to Start » National Instruments » TestStand x.x » TestStand Version Selector. Select the version of TestStand you are trying to use (even if it is the only option) and click Make Active. This will re-register all the necessary activeX components. The activeX server for database is stored in the follow location: <TestStand>\Components\NI\Models\TestStandModels\Database\ DBOptions\TsDBOptions.dll If the version selector does not fix the issue, you can try manually register this server. To do so, please following the knowledgebase in the related links section below. Related Links: Knowledgebase 1HBAMMSR: How Do I Manually Register Type Libraries, ActiveX Controls, and ActiveX Servers? Attachments:
Report Date: 02/15/2008 Last Updated: 02/19/2008 Document ID: 4IE7CCM6 |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||